Suitable for the installation into the earth, in conduits, cable duct sand are used as network cables in industrial and operational plants, mainly in LF-installations.
A-2YF(L)2Y
Suitable for the installation into the earth, in conduits, cable duct sand are used as network cables in industrial and operational plants, mainly in LF-installations.
1 ….. solid bare copper, Ø 0,6/0,8mm
2 ….. core insulation of polyethylene (PE)
3 ….. the interstices of the cable are continuously filled with jelly,
layer of plastic foil
4 ….. static screen of plastic laminated aluminium tape
5 ….. outer sheath of polyethylene (PE), black
conductor loop resistance:
core-Ø 0,6mm ….. 130,0 Ohm/km
core-Ø 0,8mm ….. 73,2 Ohm/km
Cores twisted to star-quads.
DIN VDE 0816 (core identification)
DIN EN 60228 class 1 (construction)
Peak operating voltage [V]
225 Volt
Test voltage at 50 Hz core / core [V]AC
500
Test voltage at 50 Hz core / screen [V]AC
2000
Temperature range in motion
-20°C till +50°C
Temperature range fixed
-20°C till +70°C
Bending radius in motion x diameter
15
Insulation resistance min. [MOhm/km]
1500
Mutal capacitance max. [nF/km]
52
Capacitance unbalance 100m max [pF]
800
Suitable for the installation into the earth, in conduits, cable duct sand are used as network cables in industrial and operational plants, mainly in LF-installations.
1 ….. solid bare copper, Ø 0,6/0,8mm
2 ….. core insulation of polyethylene (PE)
3 ….. the interstices of the cable are continuously filled with jelly,
layer of plastic foil
4 ….. static screen of plastic laminated aluminium tape
5 ….. outer sheath of polyethylene (PE), black
conductor loop resistance:
core-Ø 0,6mm ….. 130,0 Ohm/km
core-Ø 0,8mm ….. 73,2 Ohm/km
Cores twisted to star-quads.
DIN VDE 0816 (core identification)
DIN EN 60228 class 1 (construction)
Peak operating voltage [V]
225 Volt
Test voltage at 50 Hz core / core [V]AC
500
Test voltage at 50 Hz core / screen [V]AC
2000
Temperature range in motion
-20°C till +50°C
Temperature range fixed
-20°C till +70°C
Bending radius in motion x diameter
15
Insulation resistance min. [MOhm/km]
1500
Mutal capacitance max. [nF/km]
52
Capacitance unbalance 100m max [pF]
800
Hitra in fleksibilna dostava
Osebni pristop
Širok nabor artiklov
Skrbimo za strankine želje
Sorodni izdelki
Telecommunication cables
They are suitable for the installation into the earth, in conduits,cable ducts and are used as network cables in industr ...
Telecommunication cables
They are suitable for the installation into the earth, in conduits,cable ducts and are used as network cables in industr ...
Telecommunication cables
They are suitable for the installation into the earth, in conduits,cable ducts and are used as network cables in industr ...
Telecommunication cables
For fixed installations in all types of plants with interference and radiation hazard of the audio and communication eng ...
Telecommunication cables
For indoor installation in conduits, cable ducts or on the wall surface. This cable is suitable for the application in i ...
Telecommunication cables
They are suitable for fixed installation indoors and are used for telecommunication purposes. ...
Telecommunication cables
For indoor installation in conduits, cable ducts or on the wall surface. This cable is suitable for the application in i ...
Telecommunication cables
They are suitable for fixed installation indoors and are used for telecommunication purposes. ...