In dry, humid and wet locations, cable ducts, outdoors,underground and in water.
E-XYCY
In dry, humid and wet locations, cable ducts, outdoors,underground and in water.
1 ….. solid (RE) or stranded (RM/SM) bare copper
2 ….. core insulation of polyvinylchloride (PVC)
3 ….. PVC core covering or taping
4 ….. concentric conductor of copper wires and overlapping
copper tape
5 ….. outer sheath of polyvinylchloride (PVC) black , UV-resistant
/
adapted to ÖVE K23 and K 603
HD 603.S1
DIN EN 60228 class 1 (construction)
HD 308 S2 (core identification)
Nominale Voltage Uo/U [V]
600 / 1000 Volt
Test Voltage [V]AC
4000
Temperature range in motion
-5°C till +70°C
Temperature range fixed
-20°C till +70°C
Operating temperature Short circuit °C
160
Short circuit time max in [sec]
5
Bending radius short circuit time x diameter
12
Bending radius in motion x diameter
15
Flammability standard
EN 60332-1-2
In dry, humid and wet locations, cable ducts, outdoors,underground and in water.
1 ….. solid (RE) or stranded (RM/SM) bare copper
2 ….. core insulation of polyvinylchloride (PVC)
3 ….. PVC core covering or taping
4 ….. concentric conductor of copper wires and overlapping
copper tape
5 ….. outer sheath of polyvinylchloride (PVC) black , UV-resistant
adapted to ÖVE K23 and K 603
HD 603.S1
DIN EN 60228 class 1 (construction)
HD 308 S2 (core identification)
Nominale Voltage Uo/U [V]
600 / 1000 Volt
Test Voltage [V]AC
4000
Temperature range in motion
-5°C till +70°C
Temperature range fixed
-20°C till +70°C
Operating temperature Short circuit °C
160
Short circuit time max in [sec]
5
Bending radius short circuit time x diameter
12
Bending radius in motion x diameter
15
Flammability standard
EN 60332-1-2
Hitra in fleksibilna dostava
Osebni pristop
Širok nabor artiklov
Skrbimo za strankine želje
Sorodni izdelki
6-1 kV PVC insulated
In dry, humid and wet locations, cable ducts, outdoors,underground and in water. ...
6-1 kV PVC insulated
In dry, humid and wet locations, cable ducts, outdoors,underground and in water. ...
6-1 kV PVC insulated
In dry, humid and wet locations, cable ducts, outdoors,underground and in water. ...
6-1 kV PVC insulated
This power cable is suitable for fixed installations, preferably in cable ducts, indoors, outdoors, in water or undergro ...
6-1 kV PVC insulated
For fixed installation in indoor areas, outdoors and in the ground. ...
6-1 kV PVC insulated
This power cable is suitable for fixed installations, preferably in cable ducts, indoors, outdoors, in water or undergro ...
6-1 kV PVC insulated
In dry, humid and wet locations, cable ducts, outdoors,underground and in water. ...
6-1 kV PVC insulated
This power cable is suitable for fixed installations, preferably in cable ducts, indoors, outdoors, in water or undergro ...