For installations in dry, humid and wet locations but not outdoors.These cables are used for fix or for flexible applications – but not with high tensile load and for forced bending. Suitable as a signal and impulse cable in the control, measuring and signal technology. The copper braiding optimises protection against external interferences, like electromagnetic fields and stray frequencies.
HSLCH
For installations in dry, humid and wet locations but not outdoors.These cables are used for fix or for flexible applications – but not with high tensile load and for forced bending. Suitable as a signal and impulse cable in the control, measuring and signal technology. The copper braiding optimises protection against external interferences, like electromagnetic fields and stray frequencies.
1 ….. fine-stranded bare copper
2 ….. core insulation of halogen-free, cross-linked polyolefin
copolymere
3 ….. wrapped in a plastic foil
4 ….. screen of tinned copper wire braiding
5 ….. outer sheath of halogen-free, cross-linked
polyolefin copolymere, grey
/
adapted to DIN EN 50266-2-4 and 50267-2-2
DIN EN 60228 class 5 (construction)
core identification JZ: 1 core green/yellow, other cores black with
figures
core identification OZ: every core black with figures
Nominal voltage Uo/U [V]
300 / 500 Volt
Test voltage [V]AC
2000
Temperature range in motion
-5°C till +70°C
Temperature range fixed
-30°C till +70°C
Operating temperature short circuit °C
150
Short circuit time max. [sec]
5
Bending radius in motion x diameter
15
Flammability standard
EN 50266-2-4
EN 60332-1
For installations in dry, humid and wet locations but not outdoors.These cables are used for fix or for flexible applications – but not with high tensile load and for forced bending. Suitable as a signal and impulse cable in the control, measuring and signal technology. The copper braiding optimises protection against external interferences, like electromagnetic fields and stray frequencies.
1 ….. fine-stranded bare copper
2 ….. core insulation of halogen-free, cross-linked polyolefin
copolymere
3 ….. wrapped in a plastic foil
4 ….. screen of tinned copper wire braiding
5 ….. outer sheath of halogen-free, cross-linked
polyolefin copolymere, grey
adapted to DIN EN 50266-2-4 and 50267-2-2
DIN EN 60228 class 5 (construction)
core identification JZ: 1 core green/yellow, other cores black with
figures
core identification OZ: every core black with figures
Nominal voltage Uo/U [V]
300 / 500 Volt
Test voltage [V]AC
2000
Temperature range in motion
-5°C till +70°C
Temperature range fixed
-30°C till +70°C
Operating temperature short circuit °C
150
Short circuit time max. [sec]
5
Bending radius in motion x diameter
15
Flammability standard
EN 50266-2-4
EN 60332-1
Hitra in fleksibilna dostava
Osebni pristop
Širok nabor artiklov
Skrbimo za strankine želje
Sorodni izdelki
Halogen-free cables and wires
Suitable for fixed installations in telecommunication and are to be used in locations with fire hazard to reduce damage ...
Halogen-free cables and wires
Suitable for fixed installations in telecommunication. They are to be used in locations with fire hazard and where insul ...
Halogen-free cables and wires
For installations in dry, humid and wet locations, but not outdoors.These cables are used for fix or for flexible applic ...
Halogen-free cables and wires
Safety cables are used in all locations where a high degree of protection against fire and fire-damage has to be provide ...
Halogen-free cables and wires
Safety cables are used in all locations where a high degree of protection against fire and fire-damage has to be provide ...
Halogen-free cables and wires
For track bound vehicles and trackless trolley buses as well as for installations in dry locations, in switchboards and ...
Halogen-free cables and wires
Safety cables are used in all locations where a high degree of protection against fire and fire-damage has to be provide ...
Halogen-free cables and wires
Suitable for fixed installations in telecommunication. They are to be used in locations with fire hazard and where insul ...