It is to be used as a connection cable for reeling purposes for very high mechanical loads on movable appliances,mobile line carriers, cable carriages as well as for vertical drum operation. It is also applicable for the scope of DIN VDE 0168 and 0118, for underground and open-cast mines.
NSHTöu SMK Cordaflex
It is to be used as a connection cable for reeling purposes for very high mechanical loads on movable appliances,mobile line carriers, cable carriages as well as for vertical drum operation. It is also applicable for the scope of DIN VDE 0168 and 0118, for underground and open-cast mines.
1 ….. fine-stranded tinned copper
2 ….. PROTOLON insulated cores
3 ….. inner sheath of a special compound polychloroperene
(PCP),
antitorsion braid made of polyester threads , in a vulcanised bond
4 ….. outer sheath of wear- and tear-resistant PCP compound,
yellow,
oil-, weather- and water resistant
/
adapted to DIN VDE 0250-814
DIN EN 60228 class 5 (construction)
HD 308 S2 (core identification)
Nominal voltage Uo/U [V]
600 / 1000 Volt
Test voltage [V]AC
2500
Temperature range in motion
-35°C till +80°C
Temperature range fixed
-50°C till +80°C
Operating temperature short circuit °C
250
Short circuit time max. [sec]
5
Bending radius min. x diameter
8
Oil-resistant standard
EN 60811-2-1
Flammability standard
EN 60332-1-2
It is to be used as a connection cable for reeling purposes for very high mechanical loads on movable appliances,mobile line carriers, cable carriages as well as for vertical drum operation. It is also applicable for the scope of DIN VDE 0168 and 0118, for underground and open-cast mines.
1 ….. fine-stranded tinned copper
2 ….. PROTOLON insulated cores
3 ….. inner sheath of a special compound polychloroperene
(PCP),
antitorsion braid made of polyester threads , in a vulcanised bond
4 ….. outer sheath of wear- and tear-resistant PCP compound,
yellow,
oil-, weather- and water resistant
adapted to DIN VDE 0250-814
DIN EN 60228 class 5 (construction)
HD 308 S2 (core identification)
Nominal voltage Uo/U [V]
600 / 1000 Volt
Test voltage [V]AC
2500
Temperature range in motion
-35°C till +80°C
Temperature range fixed
-50°C till +80°C
Operating temperature short circuit °C
250
Short circuit time max. [sec]
5
Bending radius min. x diameter
8
Oil-resistant standard
EN 60811-2-1
Flammability standard
EN 60332-1-2

Hitra in fleksibilna dostava

Osebni pristop

Širok nabor artiklov

Skrbimo za strankine želje
Sorodni izdelki
Cables for cranes and hoists
It is to be used in dry, humid and wet locations as well as in the open-air as a flexible power and control cable for me ...
Cables for cranes and hoists
It is to be used in dry and humid locations as well as in the open air for frequent reeling processes and when the cable ...
Cables for cranes and hoists
To be used in dry and humid locations but not in the open-air for low and medium-level mechanical loads. This cable is s ...
Cables for cranes and hoists
Power and control cable for trolley systems, transfer lines,machine-tools, on hoisting devices, lift, crane and containe ...
Cables for cranes and hoists
To be used in dry, humid and wet locations as well as in the open air as a flexible power and control cable for medium-l ...
Cables for cranes and hoists
Power and control cable for trolley systems, transfer lines,machine-tools, on hoisting devices, lift, crane and containe ...