To the internal wiring of devices, switch arrangements andmachines as well as for the protected transfer in and on lights.
AWG
To the internal wiring of devices, switch arrangements andmachines as well as for the protected transfer in and on lights.
1 ….. fine-stranded bare copper
2 ….. PCV insulation
AWG 24 = app. 0,205mm2 AWG 14 = app. 2,080mm2
AWG 22 = app. 0,324mm2 AWG 12 = app. 3,310mm2
AWG 20 = app. 0,519mm2 AWG 10 = app. 5,261mm2
AWG 18 = app. 0,823mm2 AWG 08 = app. 8,367mm2
AWG 16 = app. 1,310mm2 AWG 06 = app. 13,30mm2
DIN EN 60228 Class 5 (construction)
UL / CSA / MTW 1015+1063
UL 758, UL 1581
CSA C 22.2 Nr. 127
Nominal voltage Uo/U [V]
600 Volt
Test voltage [V]AC
4000
Temperature range in motion
+5°C till +105°C
Temperature range fixed
-15°C till +105°C
Operating temperature short circuit °C
160
Short circuit time max. [sec]
5
Flammability standard
EN 60332-1-2
To the internal wiring of devices, switch arrangements andmachines as well as for the protected transfer in and on lights.
1 ….. fine-stranded bare copper
2 ….. PCV insulation
AWG 24 = app. 0,205mm2 AWG 14 = app. 2,080mm2
AWG 22 = app. 0,324mm2 AWG 12 = app. 3,310mm2
AWG 20 = app. 0,519mm2 AWG 10 = app. 5,261mm2
AWG 18 = app. 0,823mm2 AWG 08 = app. 8,367mm2
AWG 16 = app. 1,310mm2 AWG 06 = app. 13,30mm2
DIN EN 60228 Class 5 (construction)
UL / CSA / MTW 1015+1063
UL 758, UL 1581
CSA C 22.2 Nr. 127
Nominal voltage Uo/U [V]
600 Volt
Test voltage [V]AC
4000
Temperature range in motion
+5°C till +105°C
Temperature range fixed
-15°C till +105°C
Operating temperature short circuit °C
160
Short circuit time max. [sec]
5
Flammability standard
EN 60332-1-2

Hitra in fleksibilna dostava

Osebni pristop

Širok nabor artiklov

Skrbimo za strankine želje
Sorodni izdelki
PVC insulated wires
For indoor fixed installations in dry locations, in switchboards and distributors, installed in surface mounted or embed ...
PVC insulated wires
To the internal wiring of devices, switch arrangements and machines as well as for the protected transfer in and on ligh ...
PVC insulated wires
For protected fixed installations inside appliances and in or on lighting fittings. For installations in pipes on and un ...
PVC insulated wires
For indoor fixed installations in dry locations, in electrical equipment, switchboards and distributors. Should be insta ...
PVC insulated wires
For indoor fixed installations in dry locations, in switchboards and distributors, installed in surface mounted or embed ...
PVC insulated wires
For protected fixed installations inside appliances and in or on lighting fittings. For installations in pipes on and un ...
PVC insulated wires
For the internal wiring of switchbords, electrical equipment, e. g. households, radio or televisions and control desks. ...